Type Code Description Data Sheet
Software SAG-App SAG Configuration Tool 1.51 PDF
EVCD SAG-2101+ This barrier supports four channels concurrently. Four channels contain power and data. Data channel contains three channels for RS232 and one channel for RS485 and Power channels use to power on the device with 0-9V dc. PDF
Transmitter SAG3001+ 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Suitable for long field cables (> 1000 m), Connection via spring terminals, Up to SIL2 acc. to†IEC†61508, Input: 2-wire transmitter, Rated voltage: 19 ... 30 V DC, SIL/IEC 61508 PDF
Transmitter SAG3002+ 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1†input and 2†outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Input: 2-wire transmitter, Rated voltage: 18 ... 30 V DC, SIL/IEC 61508 PDF
Transmitter SAG3003+ 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4†mA†...†20†mA, Terminals with test points, Up to SIL2 acc.†to†IEC†61508, Input: 2-wire transmitter|3-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508 PDF
Transmitter SAG3004+ 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4†mA†...†20†mA, Terminals with test points, Up to SIL2 acc. to†IEC†61508, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508 PDF
Transmitter SAG3005+ 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/1 V ... 5 V, Terminals with test points, Up to SIL2 acc. to†IEC†61508, Input: 2-wire transmitter, Rated voltage: 20 ... 35 V DC, SIL/IEC 61508 PDF
Thermocouple SAG4001 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Input: Thermocouple, Rated voltage: 12 ... 35 V DC loop powered, Output: 4-20 mA PDF
RTD SAG5001 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4†mA†...†20†mA, Sink or source mode, Configurable by†PACTware, Line fault (LFD) and sensor burnout detection, Input: Temperature, Rated voltage: 19 ... 30 V DC, Output: 4-20 mA PDF
RTD SAG5002 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable byPACTware, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc.†to†IEC†61508/IEC†61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 0-5 V PDF
RTD SAG5003 2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4†mA†...†20†mA, Sink or source mode, Configurable byPACTware, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc. to†IEC†61508/IEC†61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 4-20 mA PDF
RTD SAG5004 2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by†PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL2 acc.†to†IEC†61508/IEC†61511, Input: Temperature, Rated voltage: 20 ... 30 V DC, Output: 0-5 V PDF
Digital I/O SAG6001 Level sensing input, Adjustable range 1 k? ... 150 k?, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 20 ... 30 V DC PDF